产品目录
点击下载
Download
详细介绍
Model Number Designation
| KA | P | 00 | -SO | -S | -0.19 | -B0 | -GL0 | -F0 | -T | |
| Series | Pump | Group | Front cover | Rotation | Displacement(ml/r) | Shaft | Port | Ports position | Seals | Options |
| S0 S1 R0 R1 (Show as below) | D-Clockwise S-Counter clockwise R-Reversible | 0.19 0.26 0.38 0.50 0.65 0.75 0.88 1.00 1.25 1.50 1.75 2.00 | B0 P0 | Omit-Side inlet and side outlet F0-Front inlet and front outlt F1-Side inlet and front outlet B1-Back inlet and front outlet B2-Back inlet and side outlet B3-Back inlet and back outlet | Omit-Range between -10C and +80 C,inlet pressure up to max.3 bar absolute. H -Version suitable for fluid at hi-temperatures, range between -10C and +120"C. L -Version suitable for fuid at low-temperatures, range between 40C and +80C. S -Version suitable fr inlet pressure up to max.3 and 6 bar absolute. T .Version suitable for inlet pressure up to max. 3 and 10 bar absolute. | D -Directional valves Drain: I0 -intemal drain E0-extemal drain φ5 E1-extemal drain G1/8 |
| Displacement | Max pressure | Max.speed | Min. speed | ||
| P1 | P2 | P3 | |||
| (cm3/rev) | bar | bar | bar | (r/min) | (r/min) |
| 0.19 | 200 | 230 | 250 | 7000 | 1000 |
| 0.26 | 200 | 230 | 250 | 7000 | 1000 |
| 0.38 | 200 | 230 | 250 | 7000 | 1000 |
| 0.50 | 200 | 230 | 250 | 7000 | 1000 |
| 0.65 | 200 | 230 | 250 | 7000 | 1000 |
| 0.75 | 200 | 230 | 250 | 7000 | 1000 |
| 0.88 | 200 | 230 | 250 | 7000 | 1000 |
| 1.00 | 200 | 230 | 250 | 6000 | 850 |
| 1.25 | 200 | 230 | 250 | 5000 | 700 |
| 1.50 | 200 | 230 | 250 | 4000 | 600 |
| 1.75 | 180 | 210 | 230 | 4000 | 600 |
| 2.00 | 160 | 190 | 210 | 3000 | 500 |

Model Number Designation
| KA | P | 11 | -CO | -D | -1.8 | B0 | GL0 | -F0 | -T | |
| Series | Pump | Group | Front cover | Rotation | Displacement(ml/r) | Shaft | Port | Ports position | Seals | Options |
| C0 | D-Clockwise S-Counter clockwise R-Reversible | 0.8 1.1 1.3 1.6 1.8 2.7 3.2 4.2 4.8 5.8 7.0 8.0 | B0 ZO | GL0 GL1 NT0 GL2 GL3 MT0 FF0 EF0 (Show as below) | Omit-Side inlet and side outlet F0-Front inlet and front outlt F1-Side inlet and front outlet B1-Back inlet and front outlet B2-Back inlet and side outlet B3-Back inlet and back outlet | Omit-Range between -10C and +80 C,inlet pressure up to max.3 bar absolute. H -Version suitable for fluid at hi-temperatures, range between -10C and +120"C. L -Version suitable for fuid at low-temperatures, range between 40C and +80C. S -Version suitable fr inlet pressure up to max.3 and 6 bar absolute. T .Version suitable for inlet pressure up to max. 3 and 10 bar absolute. | Other options available | |||
| C1 | B0 ZO Z1 | |||||||||
| C2 | B1 ZO Z1 | |||||||||
| S0 (Show as below) | B0 ZO |
| Displacement | Max pressure | Max.speed | Min. speed | ||
| P1 | P2 | P3 | |||
| (cm3/rev) | bar | bar | bar | (r/min) | (r/min) |
| 0.80 | 230 | 250 | 270 | 6000 | 1000 |
| 1.10 | 230 | 250 | 270 | 6000 | 1000 |
| 1.30 | 230 | 250 | 270 | 6000 | 1000 |
| 1.60 | 230 | 250 | 270 | 6000 | 1000 |
| 1.80 | 230 | 250 | 270 | 6000 | 1000 |
| 2.10 | 230 | 250 | 270 | 6000 | 1000 |
| 2.70 | 230 | 250 | 270 | 6000 | 800 |
| 3.20 | 210 | 230 | 250 | 5000 | 800 |
| 3.70 | 210 | 230 | 250 | 4500 | 800 |
| 4.20 | 210 | 230 | 250 | 4000 | 800 |
| 4.80 | 190 | 210 | 230 | 3500 | 600 |
| 5.80 | 190 | 210 | 230 | 3000 | 600 |
| 7.00 | 160 | 180 | 200 | 2500 | 600 |
| 8.00 | 160 | 180 | 200 | 2100 | 600 |